ENH:modify the chamber temperature to float

jira:[new]

Change-Id: Ibd7e71e8d6e7f43767ca754481ac864c73b98057
This commit is contained in:
tao wang authored and Lane.Wei committed 2023-09-22 16:21:26 +08:00
1 parent 6999b4447e
commit 23ee6bc4cd
2 files changed
+3 -3

No files matched your search

+2 -2
View File
@@ -494,7 +494,7 @@ MachineObject::MachineObject(NetworkAgent* agent, std::string name, std::string
bed_temp = 0.0f;
bed_temp_target = 0.0f;
chamber_temp = 0.0f;
chamber_temp_target = 0;
chamber_temp_target = 0.0f;
frame_temp = 0.0f;
/* ams fileds */
@@ -3141,7 +3141,7 @@ int MachineObject::parse_json(std::string payload)
}
if (jj.contains("ctt")) {
if (jj["ctt"].is_number()) {
chamber_temp_target = jj["ctt"].get<int>();
chamber_temp_target = jj["ctt"].get<float>();
}
}
/* signals */