HanifKoh 9992b585b0 Name the Filament and the Line in the Adaptive Pressure Advance Model Warning (#17033)
The slice-time warning for an invalid Adaptive Pressure Advance model
only said that the model "for one or more extruders may contain invalid
values". It now names the filament and carries the validator's message,
which identifies the line, on a second line. The check no longer stops
at the first invalid model, so every filament with one gets its own
notification.
2026-10-30 13:31:51 +08:00
HanifKoh 2cb2f0d2e7 Validate Only the Edited Variant's Adaptive PA Model and Accept Spaces in It (#16978)
* Validate Only the Edited Variant's Adaptive PA Model and Accept Spaces in It

Since pressure advance became a per-variant filament setting, the Filament
tab validated every variant column of the adaptive pressure advance model
whenever one was edited. The columns the user never touched still hold the
default placeholder, which the validator rejects, so every edit of a
multi-variant filament ended in a "Line 1: flow value must be greater than PA
value" dialog about a column the user could not see. The check now covers the
variant being edited only, as the nozzle temperature checks on the same tab do.

The validator also rejected whitespace between the values, which the model
parser accepts, so a model typed as "0.027, 8.1416, 2000.0" sliced correctly
but warned on every slice. Whitespace is now ignored before the values are
checked.

Enabling adaptive pressure advance before entering a model warned that the
model "may contain invalid values", which only meant that the placeholder is
all zeros. That case now gets its own warning saying that no measurements
have been entered.

* Keep the Empty Adaptive PA Model a Single Filament Column in Its Test

Deserializing an empty string into the model option leaves it with no
entries, and get_at on an empty vector aborts on a libstdc++ built with
assertions, as the Flatpak unit-test lanes are. Presets always hold one
column per filament, so set the value directly.
2026-10-29 12:08:50 +08:00
HanifKoh b1488b5c0c Fix Adaptive PA Speed When the Extrusion Inherits the Travel Feedrate (#16857)
The cooling buffer drops a G1 F that repeats the feedrate the preceding
travel, wipe or retraction already set, so an extrusion printed at the
travel speed reaches the adaptive pressure advance processor without a
feedrate line of its own. The processor only read standalone G1 F lines
and fell back to the last one it had seen, often the first layer's, so
the predicted pressure advance stayed at the first-layer value for the
rest of the print.

Track the feedrate every move with an F word sets, as the firmware does,
and use it for an extrusion that no G1 F precedes.