mirror of
https://github.com/OrcaSlicer/OrcaSlicer.git
synced 2026-11-25 06:47:48 -05:00
Several per-filament and per-extruder options default to a single value. When a config lists fewer values than there are filaments or nozzles, the Type1 prime tower and the pre-heat injector read past the end of the vector, and the same scene could slice to different G-code from one run to the next. - Read `filament_change_length`, `filament_change_length_nc` and `hotend_cooling_rate` with the same fallback to the first value that `get_at()` uses. - `is_nil(idx)` falls back to the first value like `get_at()` instead of reading past the end. - Skip the pre-cooling and last-layer reads when `get_extruder_id()` returns -1, and when no wall filament matches the selected category. - Bounds-check the pre-heat injector's per-filament and per-extruder reads, and use the extruder index when `physical_extruder_map` is too short. Configs that list a value for every filament and nozzle produce the same G-code as before. Adds a test that nozzle-change ramming extrudes the same length in both directions when `filament_change_length` has one value for two filaments.