mirror of
https://github.com/OrcaSlicer/OrcaSlicer.git
synced 2026-11-22 21:50:51 -05:00
* fix: keep a Full Publish copy's variant vectors and list in step A published Full entry clones the receiver's filament preset and overlays the author's values, but the copy's variant list was rewritten to the author's columns even when a variant-bearing key could not be filled from the file. That key kept the receiver's width while every reader sizes the layout from the list, so one variant silently read another variant's value. Copy a variant key only when the file carries all of the author's columns, then drop any remaining variant key whose length disagrees with the author's column count, and set the list last. filament_extruder_variant is itself a member of filament_options_with_variant and is skipped by that cleanup. The layout joins the entry's dedup key, so two entries naming one preset but carrying different variants cannot share a copy. A Full copy is detached and parentless, which also meant it never reached the receiver's saved project: get_preset_differed_for_save stored no diff without a parent, and load_project_embedded_presets dropped a preset whose inherits did not resolve. Embed a parentless preset with its whole config and resolve it over the default preset on load, mirroring the custom-root branch of the user-preset loader. A preset naming a missing parent is still dropped. Tests: a Full copy drops a variant key the file cannot fill; a parentless project-embedded preset keeps its own variants on reload. * fix: stop relabelling and truncating published filament variants Review of the previous commit found three paths that still let a Full Publish copy or a loaded preset describe variants its vectors do not hold. set_num_filaments resizes every key in m_filament_option_keys to the filament count, and two of those keys (filament_retract_length_nc and volumetric_speed_coefficients) are variant-bearing. Loading a multi-variant preset, including a saved Full copy, truncated them to the first variant, which readers then hid by clamping. Skip variant-bearing keys there, as Preset::normalize's own pass already does. A variant key the file did not carry was kept whenever its width matched the author's column count, then relabelled with the author's variant names. When the receiver lists the variants in another order, that puts one variant's value under another's name. Keep the key only when the receiver's list is the same layout, or it holds a single value; otherwise drop it and report it in skipped_keys. An imported material key that names a file column but is per-slot in this build was read positionally, returning another slot's column. Skip and report it instead. Also narrow the parentless project-embedded preset path to a filament preset that carries a variant layout, and keep a failed apply from aborting the whole project load. * test: store filament_retract_length_nc as the nullable option it is The filament count test set the key through the non-nullable accessor. The option's default is ConfigOptionFloatsNullable although the definition says coFloats, so the value was written through the wrong dynamic type and the later lookup returned null. Use the nullable accessor and assert the lookups succeed instead of dereferencing blindly.
OrcaSlicer tests
Building, running and writing tests is documented on the wiki, under How to Test.
Two files here rather than there, because coding agents only read what is in the repository: