Files
OrcaSlicer/docs
SoftFever d42123d2f1 Fix hang when MCP clicks an open printer selector (#17913)
# Description

When an MCP client clicked the printer selector on the Device or
Calibration tab while its printer list was already open, OrcaSlicer
froze at full CPU on macOS and Linux and had to be force-quit. A
person's mouse can't trigger it, because the open list takes the click
and closes before the selector sees it, but an MCP click goes straight
to the selector. That click now closes the list, as a person's click
does, and Orca's popups no longer hang on macOS and Linux when they are
asked to open while already open. The hung call's reply was misleading
as well: it said the call had not run and was safe to retry, although
its click had run. A call that has already acted now says it may have
done some or all of what was asked, and to check with `app_state` before
calling it again.

**Included:**
- **GUI:** the Device and Calibration printer selectors close their open
list on a click; `PopupWindow` ignores a second open on macOS and Linux.
- **MCP:** "not run, safe to retry" is reported only while no step of
the call has run.
- **Tests:** an automation test for the MCP reply and a slic3rutils test
for the popup.
- **Docs:** the MCP server design doc and the orca-wxwidgets skill's
popup pages.

A person's clicks behave as before on every platform, and Windows popup
behaviour is unchanged.

# Screenshots/Recordings/Graphs

<!--
> UI changes need before and after screenshots, on each platform you
tested.
> See what each kind of PR needs:
https://github.com/OrcaSlicer/OrcaSlicer/blob/main/CONTRIBUTING.md#what-each-kind-of-pr-needs
> For other changes, please attach images that can help explain them.
-->

## Tests

- Reproduced the hang on macOS over MCP with two `widget_click
{target:{class:"SideToolsPanel"}}` calls on the Device tab. With the
fix, repeated clicks open and close the list, each reply comes back in
under 100 ms, and the app stays idle and answers `app_state` afterwards.
- New tests: "a call says it was not run only until a step of it has
run" (automation) and "a popup never links its event handlers to
themselves and a second click on its control closes it" (slic3rutils).
With the popup guard disabled, the popup test fails and still runs to
the end instead of hanging.
- On this branch, macOS arm64 Release: the build passes, the automation
suite passes (186 test cases) and the slic3rutils `[Mcp]` tests pass
(508 test cases).
- Windows and Linux were not built or run; their code paths were checked
against wxWidgets' source.

<!--
> A guide for users on how to download the artifacts from this PR.
-->

[How to Download Pull Requests Artifacts for
Testing](https://www.orcaslicer.com/wiki/how_to_download_pr_artifacts)
2026-11-26 20:51:59 +08:00
..