AWS returns, as the Task result of the optimized states:startExecution
integration (measured in ap-northeast-1 on 2026-09-30):
- request-response: the StartExecution response, {ExecutionArn, StartDate},
StartDate in epoch milliseconds
- .sync: the child's DescribeExecution response, PascalCase with its keys
in alphabetical order, dates in epoch milliseconds, Input and Output as
JSON strings
- .sync:2: the same envelope with Input and Output as JSON values
Floci returned camelCase with dates in seconds for the first two and the
child's output alone for .sync:2, so a state machine written against AWS
found nothing at $.Output, $.ExecutionArn or $.Status.
The failure cause of the two .sync modes already built this envelope
(#4675). It now builds the success result too: a SUCCEEDED child carries
Output, OutputDetails and RedriveStatusReason and reports NOT_REDRIVABLE.
Request-response returns the response TaskSubmitted already records.
This changes the result shape for state machines written against Floci's
earlier one: the child output of .sync:2 moves from $ to $.Output.
Closes #4723
Co-authored-by: mitsukado-shinagawa <mitsukado-shinagawa@users.noreply.github.com>
floci-compatibility-tests
Compatibility test suite for Floci — a local AWS emulator.
Verifies that standard AWS tooling (SDKs, CDK, OpenTofu/Terraform) works correctly against the emulator without modification. Tests run against a live Floci instance and use real AWS SDK clients — no mocks.
Quick Start
# Install just (task runner)
# macOS: brew install just
# Linux: cargo install just
# Copy and configure environment
cp env.example .env
# Install dependencies
just setup
# Run all tests
just test-all
# Run specific SDK tests
just test-python
just test-typescript
just test-awscli
Test Runners
| Module | Language | Test Framework | Command |
|---|---|---|---|
sdk-test-python |
Python 3 | pytest | just test-python |
sdk-test-node |
TypeScript | vitest | just test-typescript |
sdk-test-awscli |
Bash / AWS CLI | bats-core | just test-awscli |
sdk-test-java |
Java 17 | JUnit 5 | just test-java |
sdk-test-go |
Go 1.24 | go test | just test-go |
IaC Compatibility
| Module | Tool | Command |
|---|---|---|
compat-cdk |
AWS CDK v2 | ./run.sh |
compat-opentofu |
OpenTofu | ./run.sh |
compat-terraform |
Terraform | ./run.sh |
The Terraform suite uses the standard hashicorp/aws provider against Floci's local endpoint. It validates init, validate, plan, apply, resource reads, and destroy without creating resources in a real AWS account. See the Terraform with Floci guide for a copy-paste setup.
Prerequisites
- Floci running on
http://localhost:4566(or setFLOCI_ENDPOINT) - Docker — required for Lambda invocation tests
- just — task runner for orchestration
Per-module requirements:
| Module | Requirements |
|---|---|
sdk-test-python |
Python 3.9+, pip |
sdk-test-node |
Node.js 20+, npm, vitest |
sdk-test-awscli |
AWS CLI v2, bash, jq |
sdk-test-java |
Java 17+, Maven |
sdk-test-go |
Go 1.24+ |
compat-cdk |
Node.js 20+, npm, Python 3, bats-core |
Setup
# Setup all SDKs
just setup
# Setup individual SDKs
just setup-python # pip install -r requirements.txt
just setup-typescript # npm install
just setup-awscli # Clone bats-core, bats-support, bats-assert
Running Tests
All SDKs
just test-all
Individual SDKs
# Python (pytest)
just test-python
# TypeScript (vitest)
just test-typescript
# AWS CLI (bats-core)
just test-awscli
IaC tools
The Terraform, OpenTofu, and CDK suites aren't part of just test-all — run them individually by name:
# Terraform
compat-terraform/run.sh
# OpenTofu
compat-opentofu/run.sh
# AWS CDK
compat-cdk/run.sh
Bats-based suites keep their normal console output and also write JUnit XML reports:
sdk-test-awscli/test-results/junit.xmlcompat-cdk/test-results/junit.xmlcompat-terraform/test-results/junit-<bats file>.xmlcompat-opentofu/test-results/junit-<bats file>.xml
The Terraform and OpenTofu suites run each test/*.bats file in its own process
concurrently, so they write one report per file rather than a single junit.xml.
Every consumer globs the directory, so nothing downstream changes. Set
BATS_PARALLEL_FILES=0 to run the files one at a time when isolating a failure.
Each file also runs under a BATS_FILE_TIMEOUT (default 12m): a fixture that hangs
fails under its own name with its TAP output ending at the stuck test, and the reports of
the files that finished are still published, instead of the whole job dying at the
workflow's 20 minute limit with nothing reported.
Configuration
All modules read from environment variables (see .env.example):
FLOCI_ENDPOINT=http://localhost:4566
AWS_ACCESS_KEY_ID=test
AWS_SECRET_ACCESS_KEY=test
AWS_DEFAULT_REGION=us-east-1
Running with Docker
Each module includes a Dockerfile for isolated execution:
# Python
docker build -t floci-sdk-python sdk-test-python/
docker run --rm --network host floci-sdk-python pytest
# TypeScript
docker build -t floci-sdk-node sdk-test-node/
docker run --rm --network host floci-sdk-node npm test
On macOS/Windows, use host.docker.internal instead of localhost:
docker run --rm -e FLOCI_ENDPOINT=http://host.docker.internal:4566 floci-sdk-python pytest
Exit Codes