Files
floci/compatibility-tests/sdk-test-java
Jackson Price d173d65eb4 fix(ec2): honor CopyImageTags on CopyImage (#7097)
* fix(ec2): tag an AMI with the tags RegisterImage is given

RegisterImage never read TagSpecification, so an AMI registered with
image tags came back from DescribeImages untagged: its tag filters
matched nothing and DescribeTags listed nothing for it. A tag
specification for another resource type was accepted as well, although
AWS fails that request.

RegisterImage now reads its image tag specifications and refuses any
other resource type with InvalidParameterValue. It checks the tags as
CreateTags does (no aws: prefix, the key and value lengths, at most 50
tags) before registering anything, so a refused request leaves no AMI
behind. The tags are stored before the AMI is, so DescribeImages never
lists it without them, and a key given twice keeps its last value, as
Floci's CreateTags keeps it.

Signed-off-by: Jackson Price <59149601+jprice8@users.noreply.github.com>

* fix(ec2): copy an AMI's tags when CopyImage sets CopyImageTags

CopyImage never read CopyImageTags, so a copy asked to carry its
source's tags came out untagged, and DescribeImages could not find it
by them.

With CopyImageTags=true the copy now gets the caller's tags on the
source, read in the source region, less the aws: system tags, which
AWS does not copy either. Without it, or with false, no tags are
copied, which is AWS's default. The source keeps its tags, and the
copy's are stored in the destination region only. The tags are read
under the source AMI's own id, so a catalog AMI's tags on that id are
copied too, while tags put on one of its aliases are not. Floci keeps
each account's tags apart, so another account's tags never reach the
copy.

CopyImage still neither checks nor applies TagSpecification, and the
docs now say so.

Signed-off-by: Jackson Price <59149601+jprice8@users.noreply.github.com>

* test(ec2): stub the CopyImage overload the handler calls

Upstream's handler test for CopyImage tag specifications stubbed the
five-argument copyImage. On this branch the handler passes
CopyImageTags as well, so the stub never matched, the mock returned
null and the test failed with a NullPointerException. It now stubs the
six-argument call with CopyImageTags false, which is what a request
without it sends.

Signed-off-by: Jackson Price <59149601+jprice8@users.noreply.github.com>

* refactor(ec2): leave RegisterImage tag specifications to upstream's handling

Upstream now reads RegisterImage's TagSpecification in the Query
handler, refuses other resource types and checks the tags before the
AMI is registered, so this branch's own path for the same thing is a
duplicate. The seven-argument registerImage overload and the tag code
in registerImageLocked are removed, and RegisterImage goes back to
upstream's code. CopyImage stores the tags it copies straight after it
registers the copy instead.

The branch's RegisterImage tests go too: upstream's
Ec2CreateTagSpecificationIntegrationTest and Ec2QueryHandlerTest cover
the same behaviour. What the branch adds is CopyImageTags alone.

Signed-off-by: Jackson Price <59149601+jprice8@users.noreply.github.com>

* test(ec2): pin a TagSpecification tag over a copied tag of the same key

With CopyImageTags=true and an image TagSpecification on the same
request, the copy carries both sets. When both name the same key, the
TagSpecification value is the one the copy keeps, since the handler
applies the specification after the service copies the source's tags.
The docs row says so; this test holds it.

Signed-off-by: Jackson Price <59149601+jprice8@users.noreply.github.com>

* fix(ec2): refuse a CopyImage over the tag limit before creating the copy

With CopyImageTags=true and an image TagSpecification, the copied and
the specified tags were each checked against the 50-tag limit on their
own. The service then created the AMI and its snapshots and stored the
copied tags, and only the handler's CreateTags of the specification saw
the combined set: past 50 it answered TagLimitExceeded while the copy
it had just made stayed behind, so a retry under the same Name failed
with InvalidAMIName.Duplicate.

The handler now passes the requested image tags to the service, which
checks the union of copied and requested keys before it registers
anything. The upstream handler test stubs the new signature.

The docs and the test of a key given both ways now say that the
TagSpecification value winning is Floci's behaviour: the public
CopyImage reference does not say how AWS settles that.

Signed-off-by: Jackson Price <59149601+jprice8@users.noreply.github.com>

* refactor(ec2): keep one CopyImage service signature

---------

Signed-off-by: Jackson Price <59149601+jprice8@users.noreply.github.com>
2026-10-31 15:02:38 -04:00
..

sdk-test-java

Compatibility tests for Floci using the AWS SDK for Java v2 (2.31.8).

Runs 352 tests across 17 test classes against a live Floci instance — no mocks.

Services Covered

Test class Description
SsmTest Parameter Store — put, get, path, tags
SqsTest Queues, send/receive/delete, DLQ, visibility
SnsTest Topics, subscriptions, publish, SQS delivery
S3Test Buckets, objects, tagging, copy, multipart, batch delete
DynamoDbTest Tables, CRUD, batch, TTL, tags, streams
DynamoDbScanConditionTests Scan filter and condition expressions
LambdaTest Create/invoke/update/delete functions
IamTest Users, roles, policies, access keys
StsTest GetCallerIdentity, AssumeRole, GetSessionToken
SecretsManagerTest Create/get/put/list/delete secrets, versioning, tags
KmsTest Keys, aliases, encrypt/decrypt, data keys, sign/verify
CloudWatchTest PutMetricData, ListMetrics, GetMetricStatistics, alarms
CloudFormationVirtualHostTests Virtual host style S3 access via CloudFormation
ApigwSfnJsonataCrudlTests API Gateway + Step Functions JSONata CRUDL integration
ApiGatewayV2WebSocketAndExtendedOpsTest API GW v2 WebSocket APIs, Update ops, Route/Integration Responses, Models, Tagging
Ec2Tests EC2 instances, VPCs, security groups, subnets
AppSyncTest GraphQL API CRUDL, data sources, resolvers, functions, types, API keys, tags, schema validation
EcsTests ECS clusters, task definitions, services

Adding a New Test

Create a standard JUnit 5 test class in src/test/java/com/floci/test/. Tests run against a live Floci instance using real AWS SDK clients.

Requirements

  • Java 17+
  • Maven

Running

# All tests
mvn test -q

# Specific test class
mvn test -Dtest=S3Test

# Via just (from compatibility-tests/)
just test-java

Configuration

Variable Default Description
FLOCI_ENDPOINT http://localhost:4566 Floci emulator endpoint
AWS_REGION us-east-1 Region the TestFixtures clients sign for

AWS credentials are always test / test. Setting AWS_REGION=cn-north-1 (with Floci started with FLOCI_DEFAULT_REGION=cn-north-1) runs the suite in the China partition; the nightly Partition Compatibility workflow does exactly that, and tolerates only the failures listed in .github/ci/compat-partition-allowlist-cn-north-1.txt. Tests that build their own client with an explicit region keep that region.

STS presigned identity checks

StsPresignedIdentityTest checks user and role identity over HTTP/1.1 and HTTP/2. Valid identity requests run in both modes. Forged signatures and changed bodies are sent only when signature checking is enabled. To check signature refusal, start Floci with FLOCI_AUTH_VALIDATE_SIGNATURES=true and pass the same setting to this test:

FLOCI_AUTH_VALIDATE_SIGNATURES=true mvn test -Dtest=StsPresignedIdentityTest

The test setting must match the server setting; it does not configure the server. The enabled mode also checks missing and incorrect temporary-session tokens.

Metric filter publishing checks

CloudWatchLogsMetricFilterTest and CloudFormationLogsMetricFilterTest run with the rest of the suite. Against a server on another port:

# From compatibility-tests/sdk-test-java
FLOCI_ENDPOINT=http://127.0.0.1:18084 ../../mvnw test \
  -Dtest=CloudWatchLogsMetricFilterTest,CloudFormationLogsMetricFilterTest

The publishing tests read their expected values from src/test/resources/cloudwatchlogs/metric-filter-publishing-aws.json, a byte-identical copy of the root fixture recorded from AWS. MetricFilterFixturePackagingTest checks the copy loads from the classpath, and the root CloudWatchLogsMetricFilterFixturePackagingTest fails when either SDK module copy drifts from the root file. The SDK selects the CloudWatch JSON protocol; MetricFilterQueryAssertions signs the same reads as legacy form-encoded Query requests, so GetMetricStatistics and GetMetricData on both wire formats are asserted against every statistic the fixture records (Sum, SampleCount, Minimum, Maximum). Reads poll for the sample, since the server publishes it shortly after PutLogEvents returns. Passing these tests shows Floci matches the recorded values; it is not live AWS verification. For the opt-in replay against AWS see ../sdk-test-python/README.md.

Docker

docker build -t floci-sdk-java .
docker run --rm --network host floci-sdk-java

# Custom endpoint (macOS/Windows)
docker run --rm -e FLOCI_ENDPOINT=http://host.docker.internal:4566 floci-sdk-java