mirror of
https://github.com/floci-io/floci.git
synced 2026-11-23 14:10:49 -05:00
* fix(docker): start the Windows binary with or without Docker running The 2.4.0 Windows standalone binary exited at startup with an UnsatisfiedLinkError for Java_com_sun_jna_Native_open. docker-java's named-pipe socket calls JNA when the pipe does not open at once, and JNA was initialized at image build time, so its native dispatch library was loaded into the builder and never into the binary. JNA is now initialized at run time, its JNI metadata (from oracle/graalvm-reachability-metadata, CC0) and a proxy registration for NamedPipeSocket$Kernel32 are bundled, and FlociDockerHttpClient turns a LinkageError from the transport into an exception, so a JNA that still cannot load fails that one Docker call instead of the whole emulator. With JNA working, a Windows host without Docker never answered its health check: docker-java retries a missing pipe for the whole 30 s connect timeout, and DockerRetry retried the NoSuchFileException six times. The pipe is now opened once first and a missing or denied pipe fails at once, keeping docker-java's wait loop for a busy pipe, and DockerRetry no longer retries either error. The release smoke script prints both ends of a long log on failure. Signed-off-by: Hector Ventura <hectorvent@gmail.com> * test(docker): skip the named-pipe client tests on Windows and name the tolerated exception Both tests stand a temporary directory in for a pipe, which only behaves that way off Windows: there a directory opens as access-denied and Kernel32 loads. The busy-pipe catch now names its exception expected, as AGENTS.md asks for a tolerated one. Signed-off-by: Hector Ventura <hectorvent@gmail.com> --------- Signed-off-by: Hector Ventura <hectorvent@gmail.com>
131 lines
4.6 KiB
Bash
Executable File
131 lines
4.6 KiB
Bash
Executable File
#!/usr/bin/env bash
|
|
# Smoke-tests one standalone floci-aws binary before it is published.
|
|
#
|
|
# smoke-binary.sh <binary> <expected-version>
|
|
#
|
|
# Starts the binary on a free port with in-memory storage and a scratch data
|
|
# directory, then checks that:
|
|
# 1. /_floci/health answers and reports <expected-version> (never "dev"),
|
|
# 2. SQS and DynamoDB round-trip through the AWS CLI (no Docker needed),
|
|
# 3. SIGTERM stops it cleanly within the grace period (skipped on Windows,
|
|
# where Git Bash cannot deliver a console signal to a native process).
|
|
# Requires bash, curl, Python and the AWS CLI. Exits non-zero on the first failure.
|
|
set -euo pipefail
|
|
|
|
BIN=${1:?usage: smoke-binary.sh <binary> <expected-version>}
|
|
EXPECTED=${2:?usage: smoke-binary.sh <binary> <expected-version>}
|
|
GRACE_SECONDS=${SMOKE_GRACE_SECONDS:-30}
|
|
|
|
case "$(uname -s)" in
|
|
MINGW*|MSYS*|CYGWIN*) WINDOWS=true ;;
|
|
*) WINDOWS=false ;;
|
|
esac
|
|
|
|
# Windows runners ship python, not python3.
|
|
PYTHON=$(command -v python3 || command -v python)
|
|
|
|
free_port() {
|
|
"$PYTHON" -c 'import socket; s=socket.socket(); s.bind(("127.0.0.1", 0)); print(s.getsockname()[1]); s.close()'
|
|
}
|
|
|
|
PORT=${SMOKE_PORT:-$(free_port)}
|
|
WORK=$(mktemp -d)
|
|
LOG="$WORK/floci.log"
|
|
ENDPOINT="http://127.0.0.1:$PORT"
|
|
PID=""
|
|
|
|
cleanup() {
|
|
if [ -n "$PID" ] && kill -0 "$PID" 2>/dev/null; then
|
|
kill -9 "$PID" 2>/dev/null || true
|
|
fi
|
|
rm -rf "$WORK"
|
|
}
|
|
trap cleanup EXIT
|
|
|
|
fail() {
|
|
echo "FAIL: $*" >&2
|
|
# The first exception of a failed startup is at the top of the log and its cause chain at the
|
|
# bottom, so a long log shows both ends.
|
|
if [ "$(wc -l < "$LOG" 2>/dev/null || echo 0)" -le 200 ]; then
|
|
echo "--- floci log ---" >&2
|
|
cat "$LOG" >&2 || true
|
|
else
|
|
echo "--- floci log (first 100 lines) ---" >&2
|
|
head -n 100 "$LOG" >&2 || true
|
|
echo "--- floci log (last 100 lines) ---" >&2
|
|
tail -n 100 "$LOG" >&2 || true
|
|
fi
|
|
exit 1
|
|
}
|
|
|
|
aws_local() {
|
|
AWS_ACCESS_KEY_ID=test AWS_SECRET_ACCESS_KEY=test AWS_DEFAULT_REGION=us-east-1 AWS_PAGER="" \
|
|
aws --endpoint-url "$ENDPOINT" "$@"
|
|
}
|
|
|
|
chmod +x "$BIN" 2>/dev/null || true
|
|
echo "smoke: $BIN on port $PORT, expecting version $EXPECTED"
|
|
|
|
FLOCI_STORAGE_MODE=memory \
|
|
FLOCI_STORAGE_PERSISTENT_PATH="$WORK/data" \
|
|
FLOCI_PORT="$PORT" \
|
|
QUARKUS_HTTP_PORT="$PORT" \
|
|
"$BIN" > "$LOG" 2>&1 &
|
|
PID=$!
|
|
|
|
for _ in $(seq 1 120); do
|
|
if curl -sf "$ENDPOINT/_floci/health" > "$WORK/health.json" 2>/dev/null; then
|
|
break
|
|
fi
|
|
kill -0 "$PID" 2>/dev/null || fail "the binary exited before answering /_floci/health"
|
|
sleep 0.5
|
|
done
|
|
[ -s "$WORK/health.json" ] || fail "/_floci/health did not answer within 60s"
|
|
|
|
VERSION=$("$PYTHON" -c 'import json,sys; print(json.load(open(sys.argv[1]))["version"])' "$WORK/health.json")
|
|
[ "$VERSION" = "$EXPECTED" ] || fail "/_floci/health reports version '$VERSION', expected '$EXPECTED'"
|
|
echo "ok: version $VERSION"
|
|
|
|
QUEUE_URL=$(aws_local sqs create-queue --queue-name smoke --query QueueUrl --output text) \
|
|
|| fail "sqs create-queue"
|
|
aws_local sqs send-message --queue-url "$QUEUE_URL" --message-body hello > /dev/null || fail "sqs send-message"
|
|
BODY=$(aws_local sqs receive-message --queue-url "$QUEUE_URL" --query 'Messages[0].Body' --output text) \
|
|
|| fail "sqs receive-message"
|
|
[ "$BODY" = "hello" ] || fail "sqs round trip returned '$BODY'"
|
|
echo "ok: sqs"
|
|
|
|
aws_local dynamodb create-table --table-name smoke --billing-mode PAY_PER_REQUEST \
|
|
--attribute-definitions AttributeName=id,AttributeType=S --key-schema AttributeName=id,KeyType=HASH \
|
|
> /dev/null || fail "dynamodb create-table"
|
|
aws_local dynamodb put-item --table-name smoke --item '{"id":{"S":"1"},"v":{"S":"world"}}' || fail "dynamodb put-item"
|
|
VALUE=$(aws_local dynamodb get-item --table-name smoke --key '{"id":{"S":"1"}}' --query 'Item.v.S' --output text) \
|
|
|| fail "dynamodb get-item"
|
|
[ "$VALUE" = "world" ] || fail "dynamodb round trip returned '$VALUE'"
|
|
echo "ok: dynamodb"
|
|
|
|
if [ "$WINDOWS" = true ]; then
|
|
echo "skip: graceful-shutdown check on Windows"
|
|
exit 0
|
|
fi
|
|
|
|
kill -TERM "$PID"
|
|
for _ in $(seq 1 $((GRACE_SECONDS * 2))); do
|
|
kill -0 "$PID" 2>/dev/null || break
|
|
sleep 0.5
|
|
done
|
|
if kill -0 "$PID" 2>/dev/null; then
|
|
fail "still running ${GRACE_SECONDS}s after SIGTERM"
|
|
fi
|
|
set +e
|
|
wait "$PID"
|
|
STATUS=$?
|
|
set -e
|
|
PID=""
|
|
# A JVM-style exit on SIGTERM is 143 (128 + 15); Quarkus exits 0 after a clean shutdown.
|
|
case "$STATUS" in
|
|
0|143) echo "ok: stopped on SIGTERM (exit $STATUS)" ;;
|
|
*) fail "exit status $STATUS after SIGTERM" ;;
|
|
esac
|
|
grep -q "stopped in" "$LOG" || fail "no Quarkus 'stopped in' line after SIGTERM"
|
|
echo "smoke passed: $BIN"
|